CFGGEN Utility for IBM and LSI Basic or Integrated RAID = Controllers=20 Supported controllers: - Onboard LSI 1064 SAS controller - Onboard LSI 1064e SAS controller - Onboard LSI 1068e SAS controller - Onboard LSI 1078 SAS controller - IBM SAS HBA (25R8060) - IBM 3Gb SAS HBA v2 (44E8700) - IBM SAS Expansion Card (CFFv) for IBM BladeCenter (39Y9190) - IBM SAS/SATA RAID Kit (42C1312, 42C1313) - IBM ServeRAID BR10i SAS controller (44E8688) - IBM ServeRAID BR10il SAS controller (44X0411) NOTE TO SERVICE - Reference RETAIN #N/A Version 2.10.00 - Added appropriate message indicating that MAX volume size will be = used when=20 volume size specified is bigger than drive size. - Changed the error message and usage information of auto command to be = more=20 informative about the failure of the command. - Fixed issue where the execution of CFGGEN fails with "kernel too old" = on=20 Sles9 SP4/Rhel4.8 OS. Version 2.06.01 - Fixed issue where the display command would fail when SATA devices = are attached. Version 2.06.00 - Added several fields in the output of DISPLAY. - Added support for single drive RAID 0 volumes. Version 2.00.30 - Added support for PPC platforms. - Added support for Solid State Drives (SSD) and added a check for SSD = and=20 non-SSD drive mix while creating a RAID volume or hotspare. - Added 512MB metadata support. - Fixed an issue where a hotspare drive could not be created in an = enclosure. Version 2.00.22 - Added support for PPC platforms. - Fixed issue where BIOS version was displayed in hexadecimal. - Fixed an issue where CREATE would not create a volume with 9 or 10 = drives. - Added dual hotspare support. Version 2.00.15 - Fixed an issue where, if SAS controllers are enumerated out of order, = or enumeration begins past 0, the controllers are not seen. - Fixed an issue where a resyncing volume was reported as degraded, = rather=20 than resynching. - Changed the format of the BIOS version in the DISPLAY command to = correctly=20 report versions greater than 10. Version 2.00.14 - Added <Enclosoure:Bay> support for CREATE, HOTSPARE, and FORMAT = commands. - Reformatted the output of the LIST command and added a new field. - Fixed an issue where the top byte of the subsystem vendor and device = ID=20 were truncanted in the output of the LIST command=20 - Added an 'AUTO' command to create IR volumes without the need to = specify=20 drive IDs. - Added a LOCATE command to turn the identify LED on or off on drives = in SEP devices. =20 Version 2.00.10 - Initial release